Model 626B02
Product Type: Accelerometer
View  drawing .
PERFORMANCE ENGLISH SI
Sensitivity  (± 5 %) 500 mV/g
51 mV/(m/s²) [2]
Measurement Range ± 10 g
± 98 m/s²
Frequency Range  (± 5 %) 30 to 120000 cpm
0.5 to 2000 Hz [3]
Frequency Range  (± 10 %) 22 to 240000 cpm
0.37 to 4000 Hz
Frequency Range  (± 3 dB) 12 to 360000 cpm
0.2 to 6000 Hz
Resonant Frequency 720 kcpm
12 kHz [1]
Broadband Resolution  (1 to 10,000 Hz) 20 mg
196 mm/s² [1]
Non-Linearity ± 1 %
± 1 % [4]
Transverse Sensitivity £ 7 %
£ 7 %
ENVIRONMENTAL    
Overload Limit  (Shock) 2500 g pk
24,525 m/s² pk
Temperature Range -65 to +250 °F
-54 to +121 °C
Temperature Response See Graph
See Graph
Enclosure Rating IP68
IP68
ELECTRICAL    
Settling Time  (within 1% of bias) £ 3.0 sec
£ 3.0 sec
Discharge Time Constant ³ 1.0 sec
³ 1.0 sec
Excitation Voltage 18 to 28 VDC
18 to 28 VDC
Constant Current Excitation 2 to 20 mA
2 to 20 mA
Output Impedance <100 ohms
<100 ohms
Output Bias Voltage 8 to 12 VDC
8 to 12 VDC
Spectral Noise  (10 Hz) 0.9 mg/ÖHz
8.8 (mm/s²)/ÖHz [1]
Spectral Noise  (100 Hz) 0.7 mg/ÖHz
7.0 (mm/s²)/ÖHz [1]
Spectral Noise  (1 kHz) 0.3 mg/ÖHz
3.1 (mm/s²)/ÖHz [1]
Electrical Isolation  (Case) >108 ohms
>108 ohms
PHYSICAL    
Size (Hex x Height) 1 3/16 in x 2 3/16 in
30.2 mm x 55.6 mm
Weight 7.0 oz
199 gm
Mounting Thread 1/4-28 UNF
Not Applicable [5]
Mounting Torque 2 to 5 ft-lb
2.7 to 6.8 N-m
Sensing Element Ceramic
Ceramic
Sensing Geometry Shear
Shear
Housing Material Stainless Steel
Stainless Steel
Sealing Welded Hermetic
Welded Hermetic
Electrical Connector 2-Pin MIL-C-5015
2-Pin MIL-C-5015
Electrical Connection Position Top
Top
SUPPLIED ACCESSORIES:
Model 081A40 Mounting Stud (1)
Model 085A31 Protective Thermal Jacket (1)
Model ICS-1 NIST-traceable single-axis amplitude response calibration from 600 cpm (10 Hz) to upper 5% frequency (1)
OPTIONAL VERSIONS
M - Metric Mount
Supplied Accessory : Model M081A58 Captive mounting bolt M6 x 0.75 thd 199mm long

All specifications are at room temperature unless otherwise specified.
NOTES:
[1]Typical.
[2]Conversion Factor 1g = 9.81 m/s².
[3]The high frequency tolerance is accurate within ±10% of the specified frequency.
[4]Zero-based, least-squares, straight line method.
[5]1/4-28 has no equivalent in S.I. units.
[6]See PCB Declaration of Conformance PS023 for details.



[6]



626b02  Drawing
 
Top