| PERFORMANCE |
ENGLISH |
SI |
| Alarm Threshold(± 10 %)
|
0.25 to 5 in/sec pk |
|
| Frequency Range(± 3 dB)
|
180 to 60 kcpm |
|
| Hysteresis(% < Alarm
Threshold) |
3; 6; or 10 % |
|
| Residual Vibration
Level(Reference) |
Dependent or
Independent |
| Dependent or
Independent |
[1]
| |
| Residual Vibration Level(% Alarm
Threshold) |
1 to 40 % |
|
| MAVT(Sets Alarm Threshold to 2X
actual vibration) |
Enabled or Disabled |
|
| Transverse Sensitivity
|
<7 % |
|
| Power On Delay(± 1 sec)
|
3 or 20 sec |
|
| Startup Delay(Active) |
Enabled or Disabled |
|
| Startup Delay(± 1 sec or 1
min)(Time) |
1 to 60 sec or 1 to 30
min |
| 1 to 60 sec or 1 to 30
min |
[1]
| |
| Startup Delay(x Alarm
Threshold) |
x2; x4; x8; Blocked |
|
| Operational Delay(± 1
sec) |
1 to 60 sec |
|
| Relay(Type) |
SPST, Form A or B
MOSFET |
|
| Relay(Contacts) |
Normally Open / Closed
|
| Normally Open /
Closed |
[1]
| |
| Relay(Latching) |
Latching / Non-Latching
|
| Latching /
Non-Latching |
[1]
| |
| ENVIRONMENTAL |
|
|
| Temperature
Range(Operating) |
-40 to 185 °F |
|
| Temperature
Range(Storage) |
-40 to 257 °F |
|
| Overload Limit(Shock) |
5000 g pk |
|
| Enclosure Rating |
IP68 |
|
| ELECTRICAL |
|
|
| Power Required |
24 to 240 V DC/AC 50/60
Hz |
| 24 to 240 V DC/AC 50/60
Hz |
| |
| Current Rating(Relay
Closed) |
500 mA |
|
| Leak Current(Relay Open)
|
≤ 1 mA |
|
| Electrical
Isolation(Case) |
>108 ohm
|
|
| PHYSICAL |
|
|
| Size (Hex x Height) |
1.25 in x 2.6 in |
|
| Weight |
5.2 oz |
|
| Mounting Thread |
1/4-28 Female |
|
| Mounting Torque |
3 to 5 ft-lb |
|
| Sensing Element(Internal)
|
Piezoelectric
Accelerometer |
| Piezoelectric
Accelerometer |
| |
| Housing Material |
Stainless Steel |
|
| Sealing |
Welded Hermetic |
|
| Electrical Connector |
2-Pin MIL-C-5015 |
|
| Electrical Connection
Position |
Top |
|
| SUPPLIED ACCESSORIES:
|
| Model 081A41 Mounting stud 1/4-28
socket head set screw brass tip stainless steel 5/8" long
(1) |
| OPTIONAL
VERSIONS |
| EX- Hazardous
Area Approval- contact factory for specific
approvals |
| |
| Current Rating(Relay
Closed) |
100 mA |
|
| Hazardous Area
Approval |
Cl I, Div 2, Groups
A, B, C, D; Ex nL IICT3, AEx nA IICT3 |
|
| Power Required
|
10 to 30 VDC
|
|
| Relay(Capacity) |
10 to 30 VDC, 100
mA |
|
|
|
| Supplied
Accessory : Model M081A61 Mounting Stud 1/4-28 to M6 X 1
(1) |